Header design

of air-cooled heat exchangers

REMOVABLE COVER-PLATE HEADER


This header design, with a fl anged cover plate, meets API 661 „removable cover-plate header“.

Applicable range: up to 40 bar,
> 40 bar special designs possible

a)   with through bolts (figure a)
b)   with stud bolts (figure b)
PLUG HEADER

This header design, with a plug opposite each tube end, meets requirements for API 661.

Application: Fluids under high pressure on the tube side (e.g. gases). If the plug has been removed, the tubes behind it can be cleaned, re-rolled or closed.

Applicable range: up to 250 bar,
special designs possible


BONNET HEADER, WELDED-ON (D Type)

The bonnet header with a half pipe end construction.

Application: With clean products on the inside of the tube and/or with a low leakage requirement.

Applicable range: up to 25 bar, even at higher temperatures (around 250 °C),
special designs of up to 100 bar possible